CLINICAL AND RADIOGRAPHIC EVALUATION OF TWO VERSUS FOUR IMPLANT SUPPORTED MANDIBULAR OVER-DENTURE. A ONE-YEAR PROSPECTIVE STUDY USING COMPUTER GUIDED PLANNING

Waleed Hamed Maryod1; Shereen W. Arafat2; Ahmed M. Hossam Eldin3; Mohamed A. Elbaz4
1Associate Professor of Removable Prosthodontics, MSA University
2Associate Professor of Oral & Maxillofacial Surgery, MSA University.
3Associate Professor of Oral Radiology, MSA University
4Lecturer of Oral & Maxillofacial Surgery, MSA University.

Abstract

The current study was conducted to assess and compare 2 versus 4 implant supported mandibular over-denture using computer guided planning
Material& methods: The study was conducted on 16 patients who had completely edentulous jaws. Patients were divided into 2 groups. Group A: 8 patients received 2-implant supported mandibular over-denture, and Group B: 8 patients received 4-implant supported mandibular over-denture using computer guided planning. After 4 months of healing, complete denture was connected to the implants with Locator attachment abutments. Clinical evaluation was performed through Visual Analogue Scale (VAS) to assess patients’ satisfaction after 12 months of loading. Radiographic evaluation was performed through CBCT to assess the marginal bone loss at 6, 12 months post-loading and posterior ridge resorption at 12 months post-loading. Statistical analysis of data was performed.
Results: all patients were satisfied with range of 7-10 VAS with no difference between the study groups. Group A showed significant higher marginal bone loss than group B at 6, 12 months post-loading. Group A showed significant higher values of posterior ridge resorption at 12 months post-loading.
Conclusion: increasing the number of implants from 2 to 4 in mandibular implant supported over-dentures leads to significant decrease in marginal bone loss, and residual posterior ridge resorption. But didn’t have significant influence on patient satisfaction after 12 months of function..

CLICK HERE TO CHECK THE COMPLETE ARTICLE

Post Recenti

Custom Fabricated Subperiosteal Implants for Sectional Rehabilitation of Severely Atrophic Maxillae: A Technical Note Luigi …

Bone Remodeling Around Implants with Different Macro-Design Placed in Post-Extraction Sockets: A Cone-Beam Computed Tomography …

Full-arch rehabilitation of severely atrophic maxilla with additively manufactured custom-made subperiosteal implants: A multicenter retrospective …

Additively manufactured custom-made subperiosteal implant rehabilitation for severely atrophic maxillary molar area: a technical note …

VUOI SAPERNE DI PIÙ?

CONTATTACI!