CAN BONE COMPACTION IMPROVE PRIMARY IMPLANT STABILITY? AN IN VITRO COMPARATIVE STUDY WITH OSSEODENSIFICATION TECHNIQUE

Appl. Sci. 2020, 10, 8623; doi:10.3390/app10238623
Alessandro Antonelli 1,* , Francesco Bennardo 1 , Ylenia Brancaccio 1, Selene Barone 1 , Felice Femiano 2 , Ludovica Nucci 2, Giuseppe Minervini 2 , Leonzio Fortunato 1 , Ferdinando Attanasio 1 and Amerigo Giudice 1
1 Department of Health Sciences, School of Dentistry, Magna Græcia University of Catanzaro, 88100 Catanzaro, Italy; fbennardo92@gmail.com (F.B.); ybrancaccio@gmail.com (Y.B.); barone.selene19@gmail.com (S.B.); leo@unicz.it (L.F.); ferdinando.attanasio@gmail.com (F.A.); a.giudice@unicz.it (A.G.)
2 Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania, Luigi Vanvitelli, 80138 Naples, Italy; Felice.femiano@unicampania.it (F.F.); ludovica.nucci@unicampania.it (L.N.); minervinigiuseppe@hotmail.it (G.M.)
* Correspondence: antonellicz@gmail.com; Tel.: +0961-712446

Abstract

Background: This study aims to analyze bone compaction and osseodensification techniques and to investigate how cancellous bone compaction could influence primary implant stability (PS). Methods: Two dierent surgical protocols (bone compactors—BC; osseodensification drills—OD) were compared by placing 20 implants into 20 fresh pig ribs for each procedure. Peak insertion torque (PIT) and peak removal torque (PRT) were investigated using an MGT-12 digital torque gauge, and implant stability quotient (ISQ) was analyzed using an Osstell® Beacon device. Results: Analysis of our data (T-test p < 0.05) evidenced no statistically significant dierence between BC and OD in terms of PIT (p = 0.33) or ISQ (p = 0.97). The comparison of PRT values showed a statistically significant dierence between BC and OD protocols (p = 0.009). Conclusions: Cancellous bone compaction seems to improve PS, preserving a significant amount of bone and evenly spreading trabeculae on the entire implant site. Although the PIT and ISQ values obtained are similar, the PRT values suggest a better biological response from the surrounding bone tissue. Nevertheless, a larger sample and further in vivo studies are necessary to validate the usefulness of this protocol in several clinical settings.

CLICK HERE TO CHECK THE COMPLETE ARTICLE

Post Recenti

Custom Fabricated Subperiosteal Implants for Sectional Rehabilitation of Severely Atrophic Maxillae: A Technical Note Luigi …

Bone Remodeling Around Implants with Different Macro-Design Placed in Post-Extraction Sockets: A Cone-Beam Computed Tomography …

Full-arch rehabilitation of severely atrophic maxilla with additively manufactured custom-made subperiosteal implants: A multicenter retrospective …

Additively manufactured custom-made subperiosteal implant rehabilitation for severely atrophic maxillary molar area: a technical note …

VUOI SAPERNE DI PIÙ?

CONTATTACI!